Medium Static Pressure Duct (Compact Size) ARXG24KHTAP / AOYG24KBTB
Features
- Highly efficient and quiet operation
- Small and lightweight outdoor unit
- Automatic airflow adjustment
- Low ambient operation
Capacity
6.8 kW
7.5 kW
Specification
Power source | Phase | Single-phase | |
---|---|---|---|
Voltage | 230 V | ||
Frequency | 50 Hz | ||
EGAT | Capacity | Cooling | 24000 (3100 - 27300) BTU/h |
SEER | 18.8 BTU/h | ||
Rank | 5 ★ | ||
Capacity | Cooling | 6.8 (0.9 - 8.0) kW | |
Heating | 7.5 (0.9 - 9.1) kW | ||
Input Power | Cooling | 1.890 kW | |
Heating | 1.850 kW | ||
EER | Cooling | 3.60 W/W | |
COP | Heating | 4.06 W/W | |
Pdesign | Cooling | 6.8 kW | |
Heating (-10°C) | 6.0 kW | ||
SEER | Cooling | ||
SCOP | Heating (Average) | 4.10 W/W | |
Energy Efficiency Class | Cooling | A++ | |
Heating (Average) | A+ | ||
Starting Current | 8.3 A | ||
Max. Operating Current | Cooling | 13.60 A | |
Heating | 13.60 A | ||
Annual Energy Consumption | Cooling | 366 kWh/a | |
Heating | 2048 kWh/a | ||
Moisture Removal | 1.80 l/h | ||
Sound Pressure Level*2 | Indoor (Cooling) | High | 32 dB(A) |
Middle | 28 dB(A) | ||
Low | 24 dB(A) | ||
Quiet | 21 dB(A) | ||
Indoor (Heating) | High | 32 dB(A) | |
Middle | 28 dB(A) | ||
Low | 24 dB(A) | ||
Quiet | 21 dB(A) | ||
Sound Pressure Level*2 | Outdoor (Cooling) | High | 53 dB(A) |
Outdoor (Heating) | High | 54 dB(A) | |
Sound Power Level | Indoor (Cooling) | High | 57 dB(A) |
Indoor (Heating) | High | 57 dB(A) | |
Outdoor (Cooling) | High | 65 dB(A) | |
Outdoor (Heating) | High | 66 dB(A) | |
Air Flow Rate | Indoor (Cooling) | High | 1360 m³/h |
Outdoor (Cooling) | High | 2700 m³/h | |
Static pressure range (Standard) | 30 - 200 (35) Pa | ||
Net Dimensions Indoor |
Height | 300 mm | |
Width | 1000 mm | ||
Depth | 700 mm | ||
Net Dimensions Outdoor |
Height | 716 mm | |
Width | 820 mm | ||
Depth | 315 mm | ||
Net Weight | Indoor | 36.0 kg | |
Outdoor | 42.0 kg | ||
Connection Pipe Diameter | Liquid | φ6.35 mm | |
Gas | φ12.7 mm | ||
Drain Hose Diameter | φ25(I.D.), φ32(O.D.) mm | ||
Max Pipe Length (Pre Charge) | 30.0 (20.0) m | ||
Max Height Difference | 25 m | ||
Operation Range | Cooling | -15 to 46 °CDB | |
Heating | -15 to 24 °CDB | ||
Refrigerant | Type | R32 | |
Global Warming Potential | 675 | ||
Charge | 1250 g (0.844 CO2eq–T) |
Scroll
- *2.
- The noise value is the value when measured in an anechoic room. When measured in the actual installed state,surrounding noise and reflections are received and the measured value is usually larger than the indicated value.