Cassette R32 Circular Flow Series (Comfort for Large Rooms) AUXG24KRLB / AOYG24KBTB

Indoor unit, Remote controller, Outdoor unit

ALL DC i-PAM R32 10 Years Warranty EGAT★2 NEW
Indoor Unit :
AUXG24KRLB
Outdoor Unit :
AOYG24KBTB
Download :
Catalogues

Features

  • Unique circular flow design
  • Individual louver control
  • Compact and lightweight outdoor unit
  • Low ambient operation
  • 3 Cassette Grilles to choose from

Feature Icons

Economy mode: A thermostat setting is adjusted automatically according to the room temperature to avoid unnecessary cooling or heating. Setting temperature range limitation: Sets the minimum and maximum limits on room temperature to establish the right balance between energy saving and a comfortable environment. Set temperature auto return: The setting temperature automatically returns to the previously set temperature. Auto changeover: The unit automatically switches between heating and cooling modes based on the temperature setting and the room temperature. Vertical swing louver: The louver automatically swings up and down. Automatic fan speed: A micro-computer automatically adjusts the airflow to follow the changes in room temperature. Auto restart: In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored. Connectable fresh air duct: Outside air can be introduced by attaching a locally purchased duct to the fresh air knockout and an optional part. Connectable distributing duct: Locally purchased branch ducts can be attached to the systems to distribute the airflow. Individual airflow direction control: Each louver of a 4-way Cassette type can be controlled individually to provide comfortable airflow. Auto-off timer: Automatically stops operation when a fixed time has elapsed from the start of operation. Weekly timer: Different ON-OFF times can be set for each day. Filter sign: Indicates the filter cleaning period by blinking. External ON/OFF input Special Cooling: Special Cooling Drain pump equipped as standard Blue fin

Capacity

Cooling   6.8 kW
Heating   7.5 kW


Specification

Power source Phase Single-phase
Voltage 230 V
Frequency 50 Hz
EGAT Capacity Cooling 24000 (3100 - 27300) BTU/h
SEER 20.6 BTU/h
Rank 5 ★★
Capacity Cooling 6.8 (0.9 - 8.0) kW
Heating 7.5 (0.9 - 9.1) kW
Input Power Cooling 1.890 kW
Heating 1.900 kW
EER Cooling 3.60 W/W
COP Heating 3.95 W/W
Pdesign Cooling 6.8 kW
Heating (-10°C) 6.0 kW
SEER Cooling
SCOP Heating (Average) 4.20 W/W
Energy Efficiency Class Cooling A++
Heating (Average) A+
Starting Current 8.4 A
Max. Operating Current Cooling 13.60 A
Heating 13.60 A
Annual Energy Consumption Cooling 360 kWh/a
Heating 1999 kWh/a
Moisture Removal 2.70 l/h
Sound Pressure Level*2 Indoor (Cooling) High 35 dB(A)
Middle 33 dB(A)
Low 32 dB(A)
Quiet 29 dB(A)
Indoor (Heating) High 35 dB(A)
Middle 33 dB(A)
Low 32 dB(A)
Quiet 29 dB(A)
Sound Pressure Level*2 Outdoor (Cooling) High 53 dB(A)
Outdoor (Heating) High 54 dB(A)
Sound Power Level Indoor (Cooling) High 49 dB(A)
Indoor (Heating) High 49 dB(A)
Outdoor (Cooling) High 65 dB(A)
Outdoor (Heating) High 66 dB(A)
Air Flow Rate Indoor (Cooling) High 1150 m³/h
Outdoor (Cooling) High 2700 m³/h
Net Dimensions
Indoor
Height 246 mm
Width 840 mm
Depth 840 mm
Net Dimensions
Outdoor
Height 716 mm
Width 820 mm
Depth 315 mm
Net Weight Indoor 24.0 kg
Outdoor 42.0 kg
Connection Pipe Diameter Liquid φ6.35 mm
Gas φ12.7 mm
Drain Hose Diameter φ25(I.D.), φ32(O.D.) mm
Max Pipe Length (Pre Charge) 30.0 (20.0) m
Max Height Difference 25 m
Operation Range Cooling -15 to 46 °CDB
Heating -15 to 24 °CDB
Refrigerant Type R32
Global Warming Potential 675
Charge 1250 g (0.844 CO2eq–T)
Scroll
*2.
The noise value is the value when measured in an anechoic room. When measured in the actual installed state,surrounding noise and reflections are received and the measured value is usually larger than the indicated value.

Dimensions

Indoor Unit : AUXG24KRLB

Indoor unit