Cassette R32 Circular Flow Series (Comfort for Large Rooms) AUXG24KRLB / AOYG24KBTB
Features
- Unique circular flow design
- Individual louver control
- Compact and lightweight outdoor unit
- Low ambient operation
- 3 Cassette Grilles to choose from
Capacity
6.8 kW
7.5 kW
Specification
Power source | Phase | Single-phase | |
---|---|---|---|
Voltage | 230 V | ||
Frequency | 50 Hz | ||
EGAT | Capacity | Cooling | 24000 (3100 - 27300) BTU/h |
SEER | 20.6 BTU/h | ||
Rank | 5 ★★ | ||
Capacity | Cooling | 6.8 (0.9 - 8.0) kW | |
Heating | 7.5 (0.9 - 9.1) kW | ||
Input Power | Cooling | 1.890 kW | |
Heating | 1.900 kW | ||
EER | Cooling | 3.60 W/W | |
COP | Heating | 3.95 W/W | |
Pdesign | Cooling | 6.8 kW | |
Heating (-10°C) | 6.0 kW | ||
SEER | Cooling | ||
SCOP | Heating (Average) | 4.20 W/W | |
Energy Efficiency Class | Cooling | A++ | |
Heating (Average) | A+ | ||
Starting Current | 8.4 A | ||
Max. Operating Current | Cooling | 13.60 A | |
Heating | 13.60 A | ||
Annual Energy Consumption | Cooling | 360 kWh/a | |
Heating | 1999 kWh/a | ||
Moisture Removal | 2.70 l/h | ||
Sound Pressure Level*2 | Indoor (Cooling) | High | 35 dB(A) |
Middle | 33 dB(A) | ||
Low | 32 dB(A) | ||
Quiet | 29 dB(A) | ||
Indoor (Heating) | High | 35 dB(A) | |
Middle | 33 dB(A) | ||
Low | 32 dB(A) | ||
Quiet | 29 dB(A) | ||
Sound Pressure Level*2 | Outdoor (Cooling) | High | 53 dB(A) |
Outdoor (Heating) | High | 54 dB(A) | |
Sound Power Level | Indoor (Cooling) | High | 49 dB(A) |
Indoor (Heating) | High | 49 dB(A) | |
Outdoor (Cooling) | High | 65 dB(A) | |
Outdoor (Heating) | High | 66 dB(A) | |
Air Flow Rate | Indoor (Cooling) | High | 1150 m³/h |
Outdoor (Cooling) | High | 2700 m³/h | |
Net Dimensions Indoor |
Height | 246 mm | |
Width | 840 mm | ||
Depth | 840 mm | ||
Net Dimensions Outdoor |
Height | 716 mm | |
Width | 820 mm | ||
Depth | 315 mm | ||
Net Weight | Indoor | 24.0 kg | |
Outdoor | 42.0 kg | ||
Connection Pipe Diameter | Liquid | φ6.35 mm | |
Gas | φ12.7 mm | ||
Drain Hose Diameter | φ25(I.D.), φ32(O.D.) mm | ||
Max Pipe Length (Pre Charge) | 30.0 (20.0) m | ||
Max Height Difference | 25 m | ||
Operation Range | Cooling | -15 to 46 °CDB | |
Heating | -15 to 24 °CDB | ||
Refrigerant | Type | R32 | |
Global Warming Potential | 675 | ||
Charge | 1250 g (0.844 CO2eq–T) |
Scroll
- *2.
- The noise value is the value when measured in an anechoic room. When measured in the actual installed state,surrounding noise and reflections are received and the measured value is usually larger than the indicated value.