Split DHW Integrated Type High Power Series WGYK160DG9 / WOYK112LCTA

Hydraulic unit and outdoor unit

Hydraulic Unit :
WGYK160DG9
Outdoor Unit :
WOYK112LCTA
Download :
Catalogues

Features

  • High leaving water temperature
  • High COP
  • 2-zone individual control
  • Automatic heating curve control
  • High durability
  • Emergency operation


Specifications

Capacity Range 11
7°C/35°C floor heating *1 Heating Capacity 10.80 kW
Input Power 2.51 kW
COP 4.3
2°C/35°C floor heating *1 Heating Capacity 10.77 kW
Input Power 3.40 kW
COP 3.17
-7°C/35°C floor heating *1 Heating Capacity 10.38 kW
Input Power 4.28 kW
COP 2.43
Scroll

Space Heating Characteristics *2

Temperature Application 55 °C 35 °C
Energy Efficiency Class A+ A++
Rated Heat Output 9 kW 11 kW
Seasonal Space Heating Energy Efficiency (ηs) 112 % 154 %
Annual Energy Consumption 6669 kWh 5930 kWh
Sound Power Level Hydraulic Indoor Unit 46 dB(A)
Outdoor Unit 69 dB(A)
Scroll

Domestic Hot Water Characteristics *2

Load Profile L
Energy Efficiency Class A
Energy Efficiency (ηwh) 88 %
Annual Energy Consumption 1166 kWh
Scroll

Hydraulic Indoor Unit Specifications

Power Source Phase 3 N
Voltage 400 V
Frequency 50 Hz
Net Dimensions Height 1,840 mm
Width 648 mm
Depth 698 mm
Net Weight 152 kg
Water Circulation Min./Max. 19.5 / 39.0 L/min
DHW Capacity 190 L
Hot Water Heater Capacity 1.5 kW
Expansion Vessel Capacity 12 L
Leaving Water Temperature Range Max. 60 °C
Water Pipe Connection Diameter Flow Ø 25.4 mm
Return Ø 25.4 mm
Hot Water Pipe Connection Diameter Ø 19.05 mm
Backup Heater Capacity 9.0 (3.0kW×3pcs.) kW
Scroll

Outdoor Unit Specifications

Power Source Phase 3 N
Voltage 400 V
Frequency 50 Hz
Current Max. 8.5 A
Net Dimensions Height 1,290 mm
Width 900 mm
Depth 330 mm
Net Weight 99 kg
Refrigerant (Global Warming Potential) R410A (2,088)
Refrigerant Charge 2.50 kg
Additional Refrigerant Charge 50 g/m
Connection Pipe Diameter Liquid Ø 9.52 mm
Gas Ø 15.88 mm
Pipe Length Min./Max. 5 / 20 m
Pre Charge 15 m
Height Difference Max. 15 m
Operation Range Heating -25 to 35 °C
Scroll
*1:
Heating capacity, input power, and COP are measured using the EN14511 standard. Real-world usage environments, such as the operation modes of the heating equipment, room temperature, and controller settings, may cause differences in values between these factory specifications and actual performance characteristics.
*2:
Information about ErP can be downloaded from our website at www.fujitsu-general.com/global/products/erp-ecodesign/index.html.

Dimensions

Hydraulic Unit : WGYK160DG9

Hydraulic Indoor Unit

Outdoor Unit : WOYK112LCTA

Outdoor Unit

Optional Parts

Second Circuit Kit
UTW-KZDXE
Boiler Connection Kit
UTW-KBDXD
Balancing Vessel
UTW-TEVXA
Circulating Pump
UTW-PHFXD
Swimming Pool Kit
UTW-KSPXD
Heat Exchanger for Swimming Pool Kit
UTW-ESPXA
Cooling Kit
UTW-KCLXD
Regulation Extension Kit
UTW-KREXD
Low Noise Kit
UTW-KLNXE
HMI Kit
UTW-KHMXE
Remote Controller
UTW-C74TXF
Remote Controller
UTW-C74HXF
Remote Controller
UTW-C78XD
Remote Controller
UTW-C78XD-E
Room Thermostat
UTW-C55XA
Room Thermostat
UTW-C58XD
Outdoor Sensor Transmitter
UTW-MOSXD
RF Module
UTW-MRCXD
Web Server
UTW-KW1XD
Web Server
UTW-KW4XD
LPB Clip
UTW-KL1XD
MODBUS® Clip
UTW-KMBXE
Base Heater
UTW-HAMXE
Base Heater
UTW-HAMXF
Service Tool (OCI700 Adapter included)
UTW-KSTXD
Service Tool Software
UTW-KPSXD
external connect kits
UTY-XWZXZ2
UTW-KDWXD (External),UTW-T20XA UTW-T30XA,UTW-T30XD :
DHW operation is possible without DHW Kit and DHW Tank.
UTW-KHMXE,UTW-C74TXF,UTW-C74HXF :
19 Languages included,no separate Estern European RC necessary. C74TXF: Built in Room Temperature sensor C74HXF: Built in Room temperature and Humidity sensor
UTW-C78XD-E :
Eastern European Language(English, Czech Republic, Slovakia, Poland, Turkey, Hungary, Russia, Slovenia, Greece, Serbia)
UTW-KSTXD :
UTW-KL1XD is required for the connection.
UTW-KPSXD :
UTW-KW1XD or UTW-KW4XD is required for the connection.
UTW-KMBXE :
Additional optional part necessary