Split Type Comfort Series R32 WSYA050ML3 / WOYA060KLT
Specifications
Capacity Range | 5 | |
---|---|---|
7°C/35°C floor heating *1 | Heating Capacity | 4.50 kW |
Input Power | 0.949 kW | |
COP | 4.74 | |
2°C/35°C floor heating *1 | Heating Capacity | 4.50 kW |
Input Power | 1.33 kW | |
COP | 3.39 | |
-7°C/35°C floor heating *1 | Heating Capacity | 4.40 kW |
Input Power | 1.59 kW | |
COP | 2.76 |
Scroll
Space Heating Characteristics *2
Temperature Application | 55 °C | 35 °C | |
---|---|---|---|
Energy Efficiency Class | A++ | A+++ | |
Rated Heat Output | 5 kW | 5 kW | |
Seasonal Space Heating Energy Efficiency (ηs) | 125 % | 175 % | |
Annual Energy Consumption | 3,035 kWh | 2,322 kWh | |
Sound Power Level | Hydraulic Indoor Unit | 40 dB(A) | |
Outdoor Unit | 57 dB(A) |
Scroll
Hydraulic Indoor Unit Specifications
Power Source | Phase | 1 ø |
---|---|---|
Voltage | 230 V | |
Frequency | 50 Hz | |
Net Dimensions | Height | 847 mm |
Width | 450 mm | |
Depth | 493 mm | |
Net Weight | 41 kg | |
Water Circulation | Min./Max. | 7.6 / 22.0 L/min |
Buffer Tank Capacity | 16 L | |
Expansion Vessel Capacity | 8 L | |
Leaving Water Temperature Range | Max. | 55 °C |
Water Pipe Connection Diameter | Flow | Ø 25.4 mm |
Return | Ø 25.4 mm | |
Backup Heater | Capacity | 3.0 ( ) kW |
Scroll
Outdoor Unit Specifications
Power Source | Phase | 1 ø |
---|---|---|
Voltage | 230 V | |
Frequency | 50 Hz | |
Current | Max. | 13.0 A |
Net Dimensions | Height | 632 mm |
Width | 799 mm | |
Depth | 290 mm | |
Net Weight | 39 kg | |
Refrigerant (Global Warming Potential) | R32 (675) | |
Refrigerant Charge | 0.97 kg | |
Additional Refrigerant Charge | 25 g/m | |
Connection Pipe Diameter | Liquid | Ø 6.35 mm |
Gas | Ø 12.70 mm | |
Pipe Length | Min./Max. | 3 / 30 m |
Pre Charge | 15 m | |
Height Difference | Max. | - 20 m |
Operation Range | Heating | -20 to 35 °C |
Scroll
- *1:
- Heating capacity, input power, and COP are measured using the EN14511 standard. Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and these values.
- *2:
- All information of ErP can be available for downloaded from www.fujitsu-general.com/global/support/downloads/search/
Dimensions
Hydraulic Unit : WSYA050ML3
Outdoor Unit : WOYA060KLT
Optional Parts
- Second Circuit Kit
- UTW-KZSXE
- Boiler Connection Kit
- UTW-KBSXD
- Balancing Vessel
- UTW-TEVXA
- DHW Kit
- UTW-KDWXD (External)
- DHW Tank
- UTW-T20AXH (200 Liter)
- DHW Tank
- UTW-T30AXH (300 Liter)
- DHW Tank
- UTW-T40AXH (400 Liter)
- DHW Tank
- UTW-T20BXH (200 Liter)
- DHW Tank
- UTW-T30BXH (300 Liter)
- DHW Tank
- UTW-T40BXH (400 Liter)
- Swimming Pool Kit
- UTW-KSPXD
- Heat Exchanger for Swimming Pool Kit
- UTW-ESPXA
- Cooling Kit
- UTW-KCLXD
- Regulation Extension Kit
- UTW-KREXD
- Drain Pan
- UTW-KDPXB
- Cascade Primary Kit (LPB Clip included)
- UTW-KCMXE
- Cascade Secondary Kit (LPB Clip included)
- UTW-KCSXE
- HMI Kit
- UTW-KHMXE
- Remote Controller
- UTW-C74TXF
- Remote Controller
- UTW-C74HXF
- Remote Controller
- UTW-C78XD
- Remote Controller
- UTW-C78XD-E
- Room Thermostat
- UTW-C55XA
- Room Thermostat
- UTW-C58XD
- Outdoor Sensor Transmitter
- UTW-MOSXD
- RF Module
- UTW-MRCXD
- Web Server
- UTW-KW1XD
- Web Server
- UTW-KW4XD
- LPB Clip
- UTW-KL1XD
- MODBUS® Clip
- UTW-KMBXE
- Base Heater
- UTW-HAMXE
- Base Heater
- UTW-HAMXF
- Service Tool (OCI700 Adapter included)
- UTW-KSTXD
- Service Tool Software
- UTW-KPSXD
- external connect kits
- UTY-XWZXZ2
- Back-up Heater kit
- UTW-KBHXL
- UTW-KHMXE,UTW-C74TXF,UTW-C74HXF :
- 19 Languages included,no separate Estern European RC necessary. C74TXF: Built in Room Temperature sensor C74HXF: Built in Room temperature and Humidity sensor
- UTW-C78XD-E :
- Eastern European Language(English, Czech Republic, Slovakia, Poland, Turkey, Hungary, Russia, Slovenia, Greece, Serbia)
- UTW-KSTXD :
- UTW-KL1XD is required for the connection.
- UTW-KPSXD :
- UTW-KW1XD or UTW-KW4XD is required for the connection.
- UTW-KMBXE :
- Additional optional part necessary