• News
  • 2008 Press Release
  • > Three-phase power supply compatible large-size commercial inverter air conditioners for Europe

日本語


PRESS RELEASE

December 24,2008
Fujitsu General Limited
(NO.08-N05-33)

Realizing industry's top class(*1) energy-saving performance

Three-phase power supply compatible
large-size commercial inverter air conditioners for Europe

Releasing 3 outdoor units (AOYD36LATT/AOYD45LATT/AOYD54LATT)

Our company will release three outdoor unit models of three-phase power supply compatible large-size commercial inverter air conditioners realizing industry's top class(*1) energy-saving performance for Europe at the end of December.

Recently, as global approach is required to environmental problems, higher energy-saving performance is demanded in the commercial air conditioner which consumes large ratio of electricity in the stores and offices.

Under such circumstances, our company has been tackling positively the enhancement of energy-saving performance and improvement of functions of middle and large size air conditioners.

We developed new outdoor units realizing the industry's top class(*1) energy-saving performance and complying with "three-phase power supply", "long piping" and "pleasant air flow distribution in large floor" which are required for large size air conditioners for commercial use.

In the new outdoor units, the top class(*1) energy-saving performance is realized in each capacity type (36/45/54 type) in combination with various indoor units such as ceiling cassette type, ceiling type, ducted type. Especially, in the combination of AOYD36LATT and ceiling cassette type indoor units, the energy-consumption efficiency (COP) 4.10 at cooling operation was achieved and the highest "Class A" was realized in "Energy Labeling Regulation"(*2) in the European market. Also, in other 2 models, energy-saving performance equivalent to "Class A" was achieved.

Furthermore, we are endeavoring to enhance reliability by complying with three-phase power supply used for commercial purpose and also clearing "European Harmonic Current Regulation"(*3) . Flexible installation for various properties such as stores and offices is made possible by long pipe designing of maximum pipe length 75m and "simultaneous operation multi" function realizing pleasant air conditioning in every corner of large or irregular floor by simultaneous operation of 2 – 3 indoor units with one outdoor unit is adopted.

We will make efforts for further expansion of air conditioner business by positively tackling the global environment problems.

Left ImagesRight Images

Left Images :  New outdoor unit (left) and ceiling cassette type indoor unit (right)
(AOYD36LATT/AOYD45LATT/AOYD54LATT)
Right Images :  Example of simultaneous operation multi connection
(Combination with small size ceiling cassette type indoor unit)

Main features

  1. Realizing industry's top class(*1) energy-saving performance
  2. Complying with commercial requirement such as "three-phase power supply", "long piping" and "pleasant airflow distribution in large floor"
    1. Complying with three-phase power supply used for commercial purpose and also clearing "European Harmonic Current Regulation"(*3)
    2. Widely applicable to store and office properties by long pipe compatible designing of max. 75m
    3. Adopting "simultaneous operation multi" function realizing pleasant air conditioning in every corner of large or irregular floor by simultaneous operation of 2 – 3 indoor units with one outdoor unit
    4. Adopting peak cut mode to control the electricity during high power consumption time and silent mode to reduce operation noise by controlling compressor and fan motor of outdoor unit

Realizing industry's top class(*1) energy-saving performance

High efficiency operation was realized by the combination of new outdoor unit equipped with new DC twin rotary compressor and new DC fan motor of sign wave drive system(*4) and ceiling cassette type indoor units equipped with high efficiency 3-dimentional wing, and industry's top class(*1) energy-saving performance was achieved.

Especially, in the combination of AOYD36LATT and ceiling cassette type, the energy consumption-efficiency (COP) 4.10 at cooling operation was realized.

Furthermore, in the combination of other 2 models and ceiling cassette type, the highest "Class A" was achieved in "Energy Labeling Regulation" in the European market.

Energy consumption efficiency : Cooling operation - Conventional model 3.02 (CLASS B) / New model 4.10 (CLASS A), Heating operation - Conventional model 3.23 (CLASS C) / New model 4.38 (CLASS A)
Comparison by ceiling cassette type indoor unit of three-phase power, 10kW

Complying with commercial requirement such as "three-phase power supply", "long piping" and "pleasant airflow distribution in large floor"

  1. Complying with three-phase power supply used for commercial purpose and also clearing "European Harmonic Current Regulation"(*3) (EN61000-3-2)

    In the new outdoor unit, when connected with three-phase power supply used for commercial purpose, the noise generated by inverter operation and harmonic current(*5) were reduced by adopting the newly developed three-phase power supply inverter. By this, "European Harmonic Current Regulation"(*3) (EN61000-3-2) is cleared with the product on its own, which enhances the reliability.

  2. Widely applicable to store and office properties by long pipe compatible designing of max. 75m

    Installation with high flexibility for stores and offices was realized by long pipe designing enabling maximum pipe length 75m and maximum system height difference 30m.

    Also, the expanded lineup of indoor units to be connected made presentation of various air conditioning environments possible.

  3. Adopting "simultaneous operation multi" function realizing pleasant air conditioning in every corner of large or irregular floor by simultaneous operation of 2 – 3 indoor units with one outdoor unit

    In the new outdoor unit, the piping from one outdoor unit can be branched out to maximum 3 pipes to install indoor units. By adopting this "simultaneous operation multi" function, air conditioning in every corner of large or irregular floor such as offices, stores, public facilities, halls, was realized.

  4. Adopting peak cut mode to control the electricity during high power consumption time and silent mode to reduce operation noise by controlling compressor and fan motor of outdoor unit

    By controlling compressor and fan motor through the input signal from external controller, peak cut mode to control the electricity during high power consumption time by 4 steps (100%, 75%, 50%, 0%) and silent mode to reduce operation noise by 2 steps were adopted. By this, power consumption at peak time and operation noise at midnight can be suppressed.

Main specifications/Release time/Production quantity (first year)

Performance by combination with ceiling cassette type indoor units

Model name   AOYD36LATT AOYD45LATT AOYD54LATT
Power supply V(volt)
ø
Hz(hertz)
400
3
50
400
3
50
400
3
50
Cooling capacity (max) kW
(kilowatt)
10.0
(11.4)
12.5
(14.0)
14.0
(16.0)
Heating capacity (max) kW
(kilowatt)
11.2
(14.0)
14.0
(16.2)
16.0
(18.0)
Energy consumption efficiency (cooling) kW/KW
(kilowatt par kilowatt)
4.10
(A)(*6)
3.53
(equivalent to A)(*6)
3.21
(equivalent to A)(*6)
Energy consumption efficiency (heating) kW/KW
(kilowatt par kilowatt)
4.38
(A)(*6)
3.91
(equivalent to A)(*6)
3.61
(equivalent to A)(*6)
Dimension (H × W × D) mm 1,290 × 900 × 330 1,290 × 900 × 330 1,290 × 900 × 330
Weight Kg 107.0 107.0 107.0

Release time

End of December, 2008

Production quantity

10,000 sets (first year)

Reference

Combination of new outdoor unit and indoor units

  Indoor unit
Single operation
(1 unit operation)
Indoor unit
Simultaneous multi operation
(2 unit operation)
Indoor unit
Simultaneous multi operation
(3 unit operation)
36 45 54 36 45 54 54
4-direction ceiling cassette type In case of indoor unit single operation, combination with AOYD36LATT is possible. In case of indoor unit single operation, combination with AOYD45LATT is possible. In case of indoor unit single operation, combination with AOYD54LATT is possible.        
4-direction ceiling cassette type
(compact size)
       In case of 2 indoor units simultaneous multi operation, combination with AOYD36LATT is possible.  In case of 2 indoor units simultaneous multi operation, combination with AOYD45LATT is possible.  In case of 2 indoor units simultaneous multi operation, combination with AOYD54LATT is possible.  In case of 3 indoor units simultaneous multi operation, combination with AOYD54LATT is possible.
Cassette type High static pressure   In case of indoor unit single operation, combination with AOYD45LATT is possible. In case of indoor unit single operation, combination with AOYD54LATT is possible.        
Mid static pressure In case of indoor unit single operation, combination with AOYD36LATT is possible. In case of indoor unit single operation, combination with AOYD45LATT is possible.      In case of 2 indoor units simultaneous multi operation, combination with AOYD45LATT is possible.  In case of 2 indoor units simultaneous multi operation, combination with AOYD54LATT is possible.  
Low static pressure        In case of 2 indoor units simultaneous multi operation, combination with AOYD36LATT is possible.      In case of 3 indoor units simultaneous multi operation, combination with AOYD54LATT is possible.
Ceiling type In case of indoor unit single operation, combination with AOYD36LATT is possible. In case of indoor unit single operation, combination with AOYD45LATT is possible. In case of indoor unit single operation, combination with AOYD54LATT is possible.        
Ceiling/Floor type        In case of 2 indoor units simultaneous multi operation, combination with AOYD36LATT is possible.  In case of 2 indoor units simultaneous multi operation, combination with AOYD45LATT is possible.  In case of 2 indoor units simultaneous multi operation, combination with AOYD54LATT is possible.  In case of 3 indoor units simultaneous multi operation, combination with AOYD54LATT is possible.

Note

*1 top class :
As of December 19, 2008 and according to our company's survey. (Industry's top class in the 10kW – 14kW class)
*2 Energy Labeling Regulation :
The "Energy Labeling" in Europe is the regulation to oblige the notation of energy consumption dividing energy efficiency into 7 steps from "Class A" to "Class G" and applied to the air conditioners with cooling capacity of less than 10kW (equivalent to our 36,000BTU models).
*3 European Harmonic Current Regulation :
European Harmonic Current Regulation is the regulation to suppress the influence to power supply system. (EN61000-3-2)
*4 sign wave drive system :
Control technology to aim at high efficiency, low vibration and low noise by making the current to drive compressor a sign wave.
*5 harmonic current :
Current of 3 – 25 times higher frequency of the frequency with public AC current flown when using inverter type (e.g.: 50Hz)
*6 (A) :
(A) indicates the highest "Class A" in "Energy Labeling Regulation" in Europe.

Contact details

 

Contents in each releace are at the time of release.
These contents are subject to change without prior notice.