New Release of 4 Room Cooling Only Inverter Multi Air Conditioners
and Large Wall mounted Inverter Air Conditioners

We will start selling new inverter air conditioners for overseas market from October, i.e., "4 room cooling only inverter multi air conditioners (4 indoor unit models and 1 outdoor unit model)" and "large wall mounted inverter air conditioners (2 models)".

In recent years, due to the increasing needs for energy saving and comfortable air conditioning, the demand for inverter air conditioners suitable for each area is expanding.

In order to respond to such needs, we have developed, in addition to the conventional line-up, 4 room cooling only inverter multi air conditioners of 3HP type (32,400BTU/9.5kW) excelling in the cost-performance for Southeast Asian market where cooling is always required and large wall mounted inverter air conditioners of 2.5HP type (24,200BTU/7.1kW) and 3HP type (27,300BTU/8.0kW) for world-wide market.

As for the new product of 4 room cooling only inverter air conditioner, the industry's highest efficiency(*1) has been pursued and maximum capacity of 38,000 BTU (11.2 kW) has been achieved with 3HP type by adopting high efficient DC twin rotary compressor and improving inverter control circuit.
With regard to the large wall mounted inverter air conditioner, maximum capacity of 27,300 BTU (8.0kW) has been realized and low noise operation (32dB for indoor unit and 46dB for outdoor unit) type (AST24PBA).

Furthermore, the industry's first(*2) 3HP type (AST30PBA) in the standard air conditioner category for overseas market has been developed to expand the product range.

In those new products, the easiness of installation has been enhanced by long piping connection and chargeless operation as well as by adopting the industry's first(*2) 4-step switching function (3-steps for 24,000BTU of large wall mounted inverter type) of maximum operating current conforming to the regulations of power supply capacity for residential use.

Indoor unit : ASY18VMN/24VMN,ASY9VMN/12VMN. Outdoor unit : AOY40VMNM4.
4 room cooling only inverter multi air conditioner

Indoor unit : AST24PBA/30PBA. Outdoor unit : AOT24PMAL/30PMAL.
Large wall mounted inverter air conditioner


Main features of 4 room cooling only inverter multi air conditioners and large wall mounted inverter air conditioners

  1. Realizing the industry's highest efficiency(*1) by adopting high efficient DC twin rotary compressor and improving inverter control circuit.
  2. Complying with the regulations for power supply in various areas of the world by adopting the industry's first(*2) switching function of maximum operation current.
  3. Enhancing the easiness of installation work by adopting long piping and chargeless refrigerant gas.

Realizing the industry's highest efficiency(*1) by adopting high efficient DC twin rotary compressor and improving inverter control circuit.

The high efficiency operation has been pursued by reducing inverter noise through adoption of DC twin rotary compressor and improvement of inverter control circuit. As for the 4 room cooling only inverter air conditioner, the industry's highest efficiency(*1) has been pursued and maximum capacity of 38,000 BTU (11.2 kW) has been achieved with 3HP type.
With regard to the large wall mounted inverter air conditioner, maximum capacity of 27,300 BTU (8.0kW) has been realized and low noise operation (32dB for indoor unit and 46dB for outdoor unit) has been pursued by designing high efficiency operation with 2.5HP type (AST24PBA).
In those new models, the capacity is fully utilized by the design to cool the inverter control circuit even at the time of overload (in the area where outdoor temperature is high).

DC twin rotary compressor image and Figure of Transition of COP

4 room cooling only inverter multi type

Representative model AOY40VMNMNM
Maximum capacity 38,000BTU (11.1kW) : 16.5A
Rated capacity 32,400BTU (9.5kW) : 13.5A
Model ASY9VMN ASY12VMN ASY18VMN ASY24VMN AOY40VMNM4
Noise level(Quiet) 31dB 32dB 33dB 34dB 47dB

Large wall mounted inverter type

Representative model AST24PBA
Maximum capacity 27,300BTU (8.0kW) : 14.0A
Rated capacity 24,200BTU (7.1kW) : 11.0A
Model AST24PBA AOT24PMAL
Noise level(Quiet) 32dB 46dB

Complying with the regulations for power supply in various areas of the world by adopting the industry's first(*2) switching function of maximum operation current.

The regulations for power supply in various areas of the world have been complied by adopting the industry's first(*2) 4-step switching function of maximum operation current. Especially, in the 4 room cooling only inverter multi type, the specified electric current regulation (maximum 8.5A or 11A) for Singapore HDC (Housing Corporation) has been complied.

4 room cooling only inverter multi type

Maximum operating current switching
8.5A 11A 13.5A 16.5A

Large wall mounted inverter type

Maximum operating current switching
9A 12A 14A 16.5A(30 type only)

Enhancing the easiness of installation work by adopting long piping and chargeless refrigerant gas.

The long piping connection in the high-rise housing has been made possible.
The easiness of installation work has been improved by adopting chargeless refrigerant gas using long piping.

  Max. pipe length Max. height difference Chargeless
4 room cooling only
inverter multi type
Total pipe length 70m
(Each unit 25m)
15m 70m
Large wall mounted
inverter type
30m 20m 15m

Other features

  1. Independently driven power diffuser of our own technology and up/down and right/left automatic air direction swing.
    4 room cooling only inverter multi 18/24 type, Large wall mounted inverter 24/30 type.
    By adopting variable diffuser of our own technology and up/down and right/left automatic air direction swing function, air flow is directed vertically in heating operation and horizontally in cooling operation so that air is circulated to every corner of the room.

    Independently driven power diffuser of our own technology and up/down and right/left automatic air direction swing.

  2. Photoregenerative deodorizing titanium oxide filter and Antibacterial air purifying WASABI filter.
    (Optional for large wall mounted inverter type)

    Air purifying effect has been considerably enhanced by adopting triple filter combining Photoregenerative deodorizing titanium oxide filter , Antibacterial air purifying WASABI filter and Antibacterial deodorizing pre-filter.

    Photoregenerative deodorizing titanium oxide filter and Antibacterial air purifying WASABI filter

  3. Auto restart function
    The convenience of use in the area where power supply is unstable has been improved by adopting auto restart function.
    Even in the event of power failure, the set temperature and operation mode are stored and automatically returned to the same condition as before when the power supply is restored.

Feature of each type

Feature of 4 room cooling only inverter multi air conditioner

Corresponding to wide variety of needs of users by selecting capacity from 4 indoor units.
Wide variety of needs of users for small room to wide living room can be met by selecting capacity from 4 different type of indoor units covering 2 rooms to 4 rooms.

Feature of large wall mounted inverter air conditioner

  1. Auto change over function
    Cooling, dry, air flow, heating operation can be switched automatically. Convenient function for the area where temperature difference between day and night is big.
  2. Coping with low outdoor temperature
    Can be operated even under the condition of low outdoor temperature.
    (Lowest outdoor temperature in cooling mode: 0°C, Lowest outdoor temperature in heating mode: -10°C)

Sales projection:

4 room cooling only inverter multi air conditioners:

First year 2,000 sets
2003 4,000 sets
2004 6,000 sets

Large wall mounted inverter air conditioner:

First year 15,000 sets
2003 30,000 sets
2004 40,000 sets

Main specifications

4 room cooling only inverter multi air conditioners:

Outdoor unit AOY40VMNM4
Connectable indoor
unit capacity
BTU 24,000 - 60,000
Maximum current 8.5A(230V) 11A(230V) 13.5A(230V) Full
Rated capacity BTU 24,500 29,400 32,400 32,400(230V)
kW 7.2 8.6 9.5 9.5(230V)
COP W/W 3.71 3.44 3.22 3.22
Noiselevel Quiet-Hi dB(A) 47 - 52
External dimensions H×W×D(cm) 90.0 × 90.0 × 35.0
Indoor unit ASY9VMN ASY12VMN ASY18VMN ASY24VMN
Rated capacity BTU 9,200 12,000 18,500 24,200
kW 2.7 3.5 5.4 7.1
Noiselevel Quiet-Hi dB(A) 31 - 38 32 - 39 33 - 42 34 - 45
External dimensions H×W×D(cm) 26.0 × 81.5 × 17.5 32.0 × 112.0 × 22.0

Large wall mounted inverter air conditioner:

Indoor unit AST24PBA AST30PBA
Outdoor unit AOT24PMAL AOT30PMAL
Cooling Rated capacity BTU 24,200 27,300
kW 7.1 8.0
COP W/W 2.70 2.42
Heating Rated capacity BTU 29,000 32,400
kW 8.5 9.5
COP W/W 3.10 2.86
Noiselevel Indoor unit dB(A) 32-45(Quiet-Hi) 32-45(Quiet-Hi)
Outdoor unit dB(A) 46-52(Quiet-Hi) 46-52(Quiet-Hi)
External dimensions Indoor unit H ×W ×D(cm) 32.0 ×112.0 ×22.0 32.0 ×112.0 ×22.0
Outdoor unit H ×W ×D(cm) 90.0 × 90.0 ×35.0 90.0 ×90.0 ×35.0

Note

*1,2
as of October , 2002, according to our company's survey