Medium Static Pressure Duct (Compact Size) ARXG18KHTAP

Indoor unit, Remote controller, Outdoor unit

ALL DC I-PAM V-PAM
Indoor Unit :
ARXG18KHTAP
Outdoor Unit :
AOYG18KBTB
Download :
Catalogues

Features

  • Highly efficient and quiet operation
  • Small and lightweight outdoor unit
  • Automatic airflow adjustment
  • Low ambient operation

Feature Icons

Economy mode: A thermostat setting is adjusted automatically according to the room temperature to avoid unnecessary cooling or heating. Setting temperature range limitation: Sets the minimum and maximum limits on room temperature to establish the right balance between energy saving and comfortable environment. Set temperature auto return: The set temperature automatically returns to the previous level. Auto changeover: The unit automatically switches between heating and cooling operations based on the set temperature and room temperature. Automatic fan speed: Microprocessor automatically adjusts the fan speed and airflow according to changes in room temperature. Auto restart: The unit automatically restarts in the previous operation mode when power returns after an outage. Connectable fresh air duct: Takes in outside air by attaching a supplied duct to the fresh air knockout and an optional part. Auto-off timer: The unit automatically switches off when a predetermined time has elapsed after the timer is activated. Weekly timer: Sets different On/Off times for each day of the week. Filter sign: Indicates when the filter should be cleaned. External On/Off input Automatic airflow adjustment: Determines the airflow level required in each application and adjusts the airflow volume automatically. Drain pump equipped as standard Blue fin

Capacity

Cooling   5.2 kW
Heating   6.0 kW


Specifications

Power Source Phase Single phase
Voltage 230 V
Frequency 50 Hz
Capacity Cooling 5.2 (0.9 - 5.9) kW
Heating 6.0 (0.9 - 7.5) kW
Input Power Cooling 1.360 kW
Heating 1.560 kW
EER Cooling 3.82 W/W
COP Heating 3.85 W/W
Pdesign Cooling 5.2 kW
Heating (-10°C) 4.4 kW
SEER Cooling 6.50 W/W
SCOP Heating (Average) 4.10 W/W
Energy Efficiency Class Cooling A++
Heating (Average) A+
Max. Operating Current Cooling 12.10 A
Heating 12.10 A
Annual Energy Consumption Cooling 280 kWh/a
Heating 1501 kWh/a
Moisture Removal 1.20 l/h
Sound Pressure Level*2 Indoor (Cooling) High 28 dB(A)
Middle 25 dB(A)
Low 22 dB(A)
Quiet 20 dB(A)
Indoor (Heating) High 28 dB(A)
Middle 25 dB(A)
Low 22 dB(A)
Quiet 20 dB(A)
Sound Pressure Level*2 Outdoor (Cooling) High 50 dB(A)
Outdoor (Heating) High 50 dB(A)
Sound Power Level Indoor (Cooling) High 54 dB(A)
Indoor (Heating) High 54 dB(A)
Outdoor (Cooling) High 62 dB(A)
Outdoor (Heating) High 62 dB(A)
Airflow Rate Indoor (Cooling) High 1050 m³/h
Outdoor (Cooling) High 2160 m³/h
Static Pressure Range (standard) 30 - 200 (35) Pa
Net Dimensions
Indoor
Height 300 mm
Width 1000 mm
Depth 700 mm
Net Dimensions
Outdoor
Height 632 mm
Width 799 mm
Depth 290 mm
Net Weight Indoor 35.0 kg
Outdoor 36.0 kg
Connection Pipe Diameter Liquid φ6.35 mm
Gas φ12.7 mm
Drain Hose Diameter φ25(I.D.), φ32(O.D.) mm
Max. Pipe Length (Pre Charge) 30.0 (20.0) m
Max. Height Difference 20 m
Operation Range Cooling -15 to 46 °C DB
Heating -15 to 24 °C DB
Refrigerant Type R32
Global Warming Potential 675
Charge 1020 g (0.689 CO2eq–T)
Scroll