Immunity Test
EN61000-6-1, EN61000-6-2, EN55024, EN55014-2, EN61547, EN55103-2, EN300 386, EN301 489-1, EN61326-1, EN60601-1-2, JIS T0601-1-2
Measurement item | Standard | Main performance |
---|---|---|
ESD | EN61000-4-2, IEC801-2 |
+/- 30kV Air/ Contact Discharge Horizontal / Vertical Coupling Plane |
Radiated immunity | EN61000-4-3, IEC801-3 |
Field uniformity : 80-2700MHz, 20V/m、AM/PM Feedback: 10kHz-18GHz: 30-200V/m |
EFT / burst | EN61000-4-4, IEC801-4 |
+/- 4.5kV 1φ/3φ AC460V/50A Clamp |
Surge | EN61000-4-5, IEC801-5 |
+/- 6.5kV Combination / CCITT 1φ/3φ, 50A DC/100A Telecom 2/4W |
Conducted Immunity | EN61000-4-6 | 0.15-230MHz 10V AM/PM M1, M2-M5/50A, Telecom T2/T4, Shield USB |
Power frequency magnetic field | EN61000-4-8 | 30A/m 50/60Hz 1.2 × 1.2 × 1.2m Helmholtz Coil 2.0 × 2.5m Oneturn Coil |
Dip/ Short Interruption | EN61000-4-11 | AC : 100-460V/30A, 1φ/3φ(Phase to phase test on 3φ) |